Informacje o produkcie |
|
- Double bending beam load cell
- Measuring element from Beryllium-Copper alloy
- 3000/4000 divisions O.I.M.L. R60 class C
- Protected against humidity up to 95% (N.C.)
- Single point load cell. High accuracy with off-center
loads
- 6 wire (sense) electrical connection
- Integrated on-center overload protection (must be adjusted
with 150% Ln)
|
Technical specifications
|
Nominal capacities |
7.5-10-15-20-30-50-75-100-150-200-250 |
kg |
Accuracy class |
3000/4000 |
n. OIML |
Minimum dead load |
0 |
%Ln |
Service load |
150 |
%Ln |
Safe load limit |
150 |
%Ln |
Total error |
< ± 0.013 |
%Sn |
Repeatability error |
< ± 0.01 |
%Sn |
Temperature effect on zero |
< ± 0.01 |
%Sn/5K |
Temperature effect on sensitivity |
< ± 0.006 |
%Sn/5K |
Creep error (30 minutes) |
< ± 0.012 |
%Sn/5K |
Temperature compensation |
-10 aľ +40 |
°C |
Temperature limits |
-20 aľ +50 |
°C |
Nominal sensitivity (Sn) |
2 ± 10% |
mV/V |
Nominal input voltage |
10 |
V |
Max. input voltage |
15 |
V |
Input impedance |
400 ± 20 |
Ohm |
Output impedance |
350 ± 3 |
Ohm |
No load output |
< ± 2 |
%Sn |
Insulation resistance |
>5000 |
MOhm |
Max.deflection (at Ln) |
0.2 - 0,4 |
mm |
|
|
Technical drawing
|
|
|