Informacje o produkcie |
|
- Double shear load cell
- Measuring element from stainless steel
- Hermetically sealed, fully welded
- Protected IP 68 (DIN 40050)
- Easy installation
- Available in ATEX EX version (optional)
- Application: Tanks and silos weighing systems with highly
linear and low profile requirements
|
Technical drawing
|
|
Size table
|
Technical specifications |
Nominal capacities |
5, 10, 20, 30, 50, 75 a 100 |
t |
Accuracy class |
3000 |
n. OIML |
Minimum dead
load |
0 |
%Ln |
Service load |
150 |
%Ln |
Safe load limit |
200 |
%Ln |
Total error |
< ± 0.017 |
%Sn |
Repeatability
error |
< ± 0.015 |
%Sn |
Temperature effect
on zero |
< ± 0.01 |
%Sn/5K |
Temperature effect
on sensitivity |
< ± 0.006 |
%Sn/5K |
Creep error (30
minutes) |
< ± 0.016 |
%Sn/5K |
Temperature compensation |
-10 aľ +40 |
° C |
Temperature limits |
-30 aľ +70 |
° C |
Nominal sensitivity
(Sn) |
2 ± 0.1% |
mV/V |
Nominal input
voltage |
10 |
V |
Max. input voltage |
15 |
V |
Input impedance |
800 ± 30 |
Ohm |
Output impedance |
700 ± 3 |
Ohm |
No load output |
< ± 2 |
%Sn |
Insulation resistance |
> 5000 |
MOhm |
Max.deflection
(at Ln) |
0.6 - 1 |
mm |
|
|
|