Informacje o produkcie |
|
- Double shear load cell
- Measuring element from steel alloy
- 3000 divisions O.I.M.L. R60 class C
- Hermetic, protected IP 67 (DIN 40050)
- Protected against corrosion by epoxy painting
- 6 wire (sense) electrical connection
- Available in ATEX EX version (optional)
- Application: Tanks, silos and vehicle weighing systems
with highly linear and low profile requirements.
|
Technical specifications
|
Nominal capacities |
7,5-10-15-20-25-30 |
t |
Accuracy class |
3000 |
n. OIML |
Minimum dead load |
0 |
%Ln |
Service load |
150 |
%Ln |
Safe load limit |
200 |
%Ln |
Total error |
< ± 0.017 |
%Sn |
Repeatability error |
< ± 0.015 |
%Sn |
Temperature effect on zero |
< ± 0.01 |
%Sn/5K |
Temperature effect on sensitivity |
< ± 0.006 |
%Sn/5K |
Creep error (30 minutes) |
< ± 0.016 |
%Sn/5K |
Temperature compensation |
-10 aľ +40 |
° C |
Temperature limits |
-20 aľ +7 |
° C |
Nominal sensitivity (Sn) |
2 ± 0.1% |
mV/V |
Nominal input voltage |
10 |
V |
Max. input voltage |
15 |
V |
Input impedance |
800 ± 25 |
Ohm |
Output impedance |
700 ± 3 |
Ohm |
No load output |
< ± 2 |
%Sn |
Insulation resistance |
> 5000 |
MOhm |
Max.deflection (at Ln) |
0.3 |
mm |
|
|
Technical drawing
|
|